Estimation of Lifetime Attributable Cancer Risks from Head and Abdomen Computed Tomography (CT) Examinations is an open-access, peer-reviewed research paper by Shaiful Kabir, Md. Abadat Hossain, Md. Main Uddin, Sinthia Binte Kholil, Afia Begum, Aleya Begum, published in Volume 15, Issue 8 of the International Journal of Advanced Research in Science and Technology (IJARST), a UGC-approved journal (Print ISSN 2319-1783, Online ISSN 2320-1126).
Shaiful Kabir, Md. Abadat Hossain, Md. Main Uddin, Sinthia Binte Kholil, Afia Begum, Aleya Begum
Computed tomography (CT) examinations contribute substantially to patient radiation exposure and may increase the risk of radiation-induced cancer. Estimating these risks is essential for optimizing radiation protection and supporting appropriate clinical use of CT imaging. This cross-sectional study included 76 patients undergoing head and abdomen CT examinations at Square Hospital, Dhaka, Bangladesh. Radiation doses were measured using thermoluminescent dosimeters (TLDs) and a 64-slice CT scanner. Effective doses were calculated from the dose-length product (DLP) using age-dependent conversion coefficients recommended in the European Guidelines on Quality Criteria for Computed Tomography (European Commission, EUR 16262 EN). Organ doses were converted into lifetime attributable risks (LARs) of cancer incidence and mortality using the Biological Effects of Ionizing Radiation VII (BEIR VII) risk model. LAR varied according to CT examination type, patient age, sex, and absorbed dose. For abdomen CT, the mean LAR of cancer incidence was 22.4 and 13.3 per 100,000 persons in males and females, respectively, with corresponding mortality risks of 5.2 and 4.1. For head CT, the mean LAR of cancer incidence was 136 and 113 per 100,000 persons, with mortality risks of 80.3 and 60.6, respectively. Younger patients demonstrated higher estimated risks, and effective dose increased with both DLP and tube current time product (mAs). Although the estimated LAR associated with head and abdomen CT examinations was relatively low, cancer risk varied according to patient age, sex, examination type, and radiation dose. The findings support patient-specific CT protocols and optimization of scanning parameters in accordance with the ALARA principle to minimize radiation exposure while maintaining diagnostic image quality, particularly for younger patients and higher-dose CT examinations.
Keywords: Computed tomography; radiation dose; effective dose; organ dose; lifetime attributable risk.
DOI: https://doi.org/10.62226/ijarst20262764
REFERENCES
[1] F. Anazor, V. Sibanda, A. Abubakar, and B. S. Dhinsa, “Computed Tomography Scan Architectural Measurements in Adult Foot and Ankle Surgery: A Narrative Review for Orthopaedic Trainees,” Cureus, Nov. 2022, doi: 10.7759/cureus.32039.
[2] Y. J. Kim, H.-J. Lee, K. G. Kim, and S. H. Lee, “The Effect of CT Scan Parameters on the Measurement of CT Radiomic Features: A Lung Nodule Phantom Study,” Comput. Math. Methods Med., vol. 2019, pp. 1–12, Feb. 2019, doi: 10.1155/2019/8790694.
[3] L. Albadarneh et al., “Investigation of lifetime attributable risk associated with brain CT scans: A retrospective study in North Jordan,” Radiat. Phys. Chem., vol. 223, p. 111931, Oct. 2024, doi: 10.1016/j.radphyschem.2024.111931.
[4] M. H. Jamshidi, A. Karami, J. Ordoni, and S. Bijari, “Estimation of Lifetime Attributable Risk (LAR) of Cancer Associated with Chest Computed Tomography Procedures in Children,” Front. Biomed. Technol., Sep. 2023, doi: 10.18502/fbt.v10i4.13726.
[5] L. Yu et al., “Radiation dose reduction in computed tomography: techniques and future perspective,” Imaging Med., vol. 1, no. 1, pp. 65–84, Oct. 2009, doi: 10.2217/iim.09.5.
[6] R. Mahmoudi, N. Jabbari, M. Aghdasi, and H. R. Khalkhali, “Energy Dependence of Measured CT Numbers on Substituted Materials Used for CT Number Calibration of Radiotherapy Treatment Planning Systems,” PLOS ONE, vol. 11, no. 7, p. e0158828, Jul. 2016, doi: 10.1371/journal.pone.0158828.
[7] G. C. Barnett et al., “Normal tissue reactions to radiotherapy: towards tailoring treatment dose by genotype,” Nat. Rev. Cancer, vol. 9, no. 2, pp. 134–142, Feb. 2009, doi: 10.1038/nrc2587.
[8] F. A. Mettler, W. Huda, T. T. Yoshizumi, and M. Mahesh, “Effective Doses in Radiology and Diagnostic Nuclear Medicine: A Catalog,” Radiology, vol. 248, no. 1, pp. 254–263, Jul. 2008, doi: 10.1148/radiol.2481071451.
[9] W. Huda and A. Vance, “Patient Radiation Doses from Adult and Pediatric CT,” Am. J. Roentgenol., vol. 188, no. 2, pp. 540–546, Feb. 2007, doi: 10.2214/AJR.06.0101.
[10] M. S. Pearce et al., “Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study,” The Lancet, vol. 380, no. 9840, pp. 499–505, Aug. 2012, doi: 10.1016/S0140-6736(12)60815-0.
[11] S. Kabir, M. Z. Hasan, D. Das, M. Raihan, A. Begum, and A. Begum, “Estimation of Lifetime Attributable Risks of Cancer Associated with Chest Computed Tomography Imaging,” Prog. Med. Phys., vol. 36, no. 1, pp. 14–24, Mar. 2025, doi: 10.14316/pmp.2025.36.1.14.
[12] W. Huda and F. A. Mettler, “Volume CT Dose Index and Dose-Length Product Displayed during CT: What Good Are They?,” Radiology, vol. 258, no. 1, pp. 236–242, Jan. 2011, doi: 10.1148/radiol.10100297.
[13] N. R. Council, D. on E. and L. Studies, B. on R. E. Research, and C. to A. H. R. from E. to L. L. of I. Radiation, Health Risks from Exposure to Low Levels of Ionizing Radiation: BEIR VII Phase 2. National Academies Press, 2006.
[14] J. K. Hoang et al., “Lifetime Attributable Risk of Cancer From Radiation Exposure During Parathyroid Imaging: Comparison of 4D CT and Parathyroid Scintigraphy,” Am. J. Roentgenol., vol. 204, no. 5, pp. W579–W585, May 2015, doi: 10.2214/AJR.14.13278.
[15] Bagherzadeh S, Jabbari N, Khalkhali HR. Estimation of lifetime attributable risks (LARs) of cancer associated with abdominopelvic radiotherapy treatment planning computed tomography (CT) simulations. Int J Radiat Biol. 2018;94:454-461.
[16] R. Smith-Bindman et al., “Radiation Dose Associated With Common Computed Tomography Examinations and the Associated Lifetime Attributable Risk of Cancer,” Arch. Intern. Med., vol. 169, no. 22, pp. 2078–2086, Dec. 2009, doi: 10.1001/archinternmed.2009.427.
[17] Valentin J. Annals of the ICRP: the 2007 Recommendations of the International Commission on Radiological Protection. The International Commission on Radiological Protection; 2007.
[18]. Wrixon AD. New ICRP recommendations. J Radiol Prot. 2008;28:161-168.
[19]. E. K. Osei and J. Darko, A Survey of Organ Equivalent and Effective Doses from Diagnostic Radiology Procedures. Clinical Stu., vol. 2013, no. 1, pp. 1-9, Sep. 2012.
[20] B. Huang, J. Li, M. W.-M. Law, J. Zhang, Y. Shen, and P. L. Khong, “Radiation dose and cancer risk in retrospectively and prospectively ECG-gated coronary angiography using 64-slice multidetector CT,” Br. J. Radiol., vol. 83, no. 986, pp. 152–158, Feb. 2010, doi: 10.1259/bjr/29879495.
[21] European Commission. European Guidelines on Quality Criteria for Computed Tomography. Report EUR 16262 EN. Luxembourg: Office for Official Publications of the European Communities; 1999.
10.62226/ijarst20262764
PAGES : 2465-2473 | 12 VIEWS | 6 DOWNLOADS
Shaiful Kabir, Md. Abadat Hossain, Md. Main Uddin, Sinthia Binte Kholil, Afia Begum, Aleya Begum — “Estimation of Lifetime Attributable Cancer Risks from Head and Abdomen Computed Tomography (CT) Examinations.” International Journal of Advanced Research in Science and Technology (IJARST), Volume 15, Issue 8. DOI: 10.62226/ijarst20262764.
Shaiful Kabir, Md. Abadat Hossain, Md. Main Uddin, Sinthia Binte Kholil, Afia Begum, Aleya Begum | Estimation of Lifetime Attributable Cancer Risks from Head and Abdomen Computed Tomography (CT) Examinations | DOI : 10.62226/ijarst20262764
| Journal Frequency: | ISSN 2320-1126, Monthly | |
| Paper Submission: | Throughout the month | |
| Acceptance Notification: | Within 6 days | |
| Subject Areas: | Engineering, Science & Technology | |
| Publishing Model: | Open Access | |
| Publication Fee: | USD 60 USD 50 | |
| Publication Impact Factor: | 6.76 | |
| Certificate Delivery: | Digital |