Khaled e albuloushi, Salman dawood alhussaini
Abstract:
Conventional vapor-compression air conditioning systems suffer from a fundamental inefficiency: the coupled processes of sensible cooling and latent dehumidification. To remove moisture, the evaporator coil must operate at an excessively low temperature, often necessitating subsequent reheating of the overcooled air to maintain comfort. This cycle of overcooling and reheating constitutes a significant source of energy waste. This paper critiques the limitations of this traditional approach and proposes a transformative alternative: the decoupling of dehumidification and sensible cooling. By employing dedicated systems, such as desiccant dehumidifiers for latent load and high-temperature cooling units for sensible load, this method eliminates the need for reheat and allows each system to operate at its peak efficiency. The decoupled system demonstrates the potential for energy savings of up to 35%, while also providing superior independent control over temperature and humidity, enhanced adaptability to part-load conditions, and improved indoor air quality. This approach represents a promising paradigm shift for enhancing energy efficiency in modern air conditioning.
References:
1. ASHRAE. (2021). ASHRAE Handbook—Fundamentals. American Society of Heating, Refrigerating and Air-Conditioning Engineers.
2. Zhang, L., & Niu, J. (2003). Energy Performance of Independent Humidity Control Air-Conditioning System with Desiccant Wheel. Energy and Buildings.
3. Gatley, D. P. (2000). The 100% Outdoor Air System: The Dehumidification Solution. Heating/Piping/Air Conditioning Engineering (HPAC).
4. Khalid, A., Mahmood, M. H., Aslam, M., & ul Haq, I. (2019). A Comprehensive Review of Dedicated Outdoor Air Systems (DOAS): Advancements, Challenges, and Opportunities. Energy and Buildings.
5. Shan, K., Wang, X., & Sun, Y. (2016). Energy Saving Potential of a Desiccant-Assisted Separate Sensible and Latent Cooling System. Applied Thermal Engineering.
6. Coad, W. J. (1999). Conditioning Ventilation Air for Improved Performance and Air Quality. HPAC Engineering.
7. ASHRAE. (2019). *Standard 62.1-2019: Ventilation for Acceptable Indoor Air Quality*. American Society of Heating, Refrigerating and Air-Conditioning Engineers.
8. Harriman, L., Plager, D., & Kosar, D. (1997). Dehumidification and Cooling Loads from Ventilation Air.
9. Wang, S. K. (2000). Handbook of Air Conditioning and Refrigeration (2nd ed.). McGraw-Hill.
10. Harriman, L., Brundrett, G., & Kittler, R. (2008). Humidity Control Design Guide for Commercial and Institutional Buildings. ASHRAE.
https://doi.org/10.62226/ijarst20252597
PAGES : 1711-1717 | 4 VIEWS | 2 DOWNLOADS
Khaled e albuloushi, Salman dawood alhussaini | Separating Cooling and Dehumidification: A Path to Greater Efficiency | DOI : https://doi.org/10.62226/ijarst20252597
| Journal Frequency: | ISSN 2320-1126, Monthly | |
| Paper Submission: | Throughout the month | |
| Acceptance Notification: | Within 6 days | |
| Subject Areas: | Engineering, Science & Technology | |
| Publishing Model: | Open Access | |
| Publication Fee: | USD 60 USD 50 | |
| Publication Impact Factor: | 6.76 | |
| Certificate Delivery: | Digital |